sorabji.com > foundcrap > found floppies > specdisk


������������������������ SECTION 07415

 

������������ PREFORMED METAL ROOF AND WALL PANELS

This section is based on preformed metal roof, wall, ceiling and soffit systems manufactured by ATAS Aluminum Corporation.� Headquartered in Allentown, PA, ATAS also has satellite manufacturing, service and warehouse facilities in San Diego, California.� ATAS produces many different types of preformed and prefinished enclosure systems in both aluminum and galvanized/Galvalume(R) steel for varied applications.

 

For more information or design assistance, contact ATAS as follows:

�� ATAS Aluminum Corporation

�� 6612 Snowdrift Road

�� Allentown, PA� 18106

�� Telephone:� 610-395-8445;� FAX:� 610-395-9342

 

ATAS also has a catalog by Fax program, available on a 24-hour basis.� Call 1-800-4-FAXCAT, follow the prompts, enter the code name for the product you are interested in, and ATAS will fax you pertinent data.

 

PART 1� GENERAL

 

1.1 SECTION INCLUDES

Delete items below not required for project.

��� A.� Preformed aluminum roof panels.

 

��� B.� Preformed steel roof panels.

 

��� C.� Preformed aluminum wall panels.

 

��� D.� Preformed steel wall panels.

 

��� E.� Preformed aluminum ceiling and soffit system.

 

��� F.� Flashings, fasteners, and accessories as required for weatherproof installation.

 

1.2 RELATED SECTIONS

Delete any sections below not relevant to this project; add others as required.

��� A.� Section 05120 - Structural Steel:� Building frame.

 

��� B.� Section 05400 - Cold Formed Metal Framing:� Exterior stud wall framing system.

 

��� C.� Section 07191 - Vapor Retarders.

 

��� D.� Section 07620 - Sheet Metal Flashing and Trim.

 

��� E.� Section 07900 - Joint Sealers.

 

��� F.� Section 08520 - Aluminum Windows.

 

��� G.� Section 13121 - Pre-Engineered Buildings:� Building framing system.

 

1.3 REFERENCES

Delete references from the list below that are not actually required by the text of the edited section.

��� A.� AAMA 607.1 - Voluntary Guide Specification and Inspection Methods for Clear Anodic Finishes for Architectural Aluminum;� American Architectural Manufacturers Association.

 

��� B.� AAMA 608.1 - Voluntary Guide Specification and Inspection Methods for Electrolytically Deposited Color Anodic Finishes for Architectural Aluminum;� American Architectural Manufacturers Association.

 

��� C.� ASTM A 446/A 446M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) by the Hot-Dip Process, Structural (Physical) Quality.

 

��� D.� ASTM A 755/A 755M - Standard Specification for Steel Sheet, Metallic Coated by the Hot-Dip Process and Prepainted by the Coil Coating Process for Exterior Exposed Building Products.

 

��� E.� ASTM A 792 - Standard Specification for Steel Sheet, 55% Aluminum-Zinc Alloy-Coated by the Hot-Dip Process, General Requirements.

 

��� F.� ASTM B 209 - Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate.

 

1.4 PERFORMANCE REQUIREMENTS

 

��� A.� Wind Loading:� Design and size components to withstand dead and live loads caused by wind pressures as follows:

������� 1.� Positive pressure:� _______ psf normal to panel.

������� 2.� Negative pressure:� _______ psf normal to panel.

 

��� B.� Maximum Deflection under Design Loads:� 1/180 of span.

 

��� C.� System Movement:� Accommodate movements due to thermal expansion and contraction, dynamic loading, and deflection of structural support system without damage to panel system or loss of weatherproofing capability.

 

��� D.� Drainage: Provide positive drainage to exterior for moisture entering building enclosure or condensation occurring within exterior building envelope.

 

1.5 SUBMITTALS

 

��� A.� Submit under provisions of Section 01300.

 

��� B.� Product Data:� Submit manufacturer's current product specifications and installation instructions.

 

��� C.� Shop Drawings:� Include small scale roof plan and elevations, as required.� Show details of trim and flashing conditions, fastening and anchorage methods, weatherproofing techniques, terminations, and penetrations.

 

��� D.� Selection Samples:� Submit actual metal chips with full range of colors available for Architect's selection.

 

��� E.� Verification Samples:� Submit two samples of each type of metal panel required, not less than 12 inches, and illustrating finished panel profile, color, sheen, and texture.

 

��� F.� Test Reports:� Submit copies of test reports verifying performance capability of panel system.

 

1.6 QUALITY ASSURANCE

 

��� A.� Installer:� Company specializing in the type of work required for this project, with not less than 2 years of documented experience.

 

��� B.� Pre-Installation Meeting:� Convene meeting not less than one week prior to beginning installation.� Comply with provisions of Section 01039.

 

1.7 DELIVERY, STORAGE, AND HANDLING

 

��� A.� Comply with provisions of Section 01600.

 

��� B.� Do not deliver materials of this section to project site until suitable facilities for storage and protection are available.

 

��� C.� Protect materials from damage during transit and at project site.� Store under cover but sloped to provide positive drainage.� Do not expose materials with��� strippable protective film to direct sunlight or extreme heat.

 

��� D.� Do not allow storage of other materials or allow staging of other work on installed metal panel roof system.

 

1.8 PROJECT CONDITIONS

 

��� A.� Take field measurements prior to fabrication of panel system.� If schedule will not permit prior field measurement, allow adequate tolerances in fabricated components to accommodate anticipated variation in project conditions.��

 

1.9 WARRANTY

 

��� A.� Comply with provisions of Section 01700.

Retain the following paragraph for Kynar 500(R)/Hylar 5000(R) fluoropolymer finish.

��� B.� Submit manufacturer's standard 20 year finish warranty for color retention, adhesion, and freedom from chalking.

 

��� C.� Submit 2 year weathertightness and workmanship warranty from installer.

 

 

PART 2� PRODUCTS

 

2.1 MANUFACTURERS

 

��� A.� Design is based on products manufactured by ATAS Aluminum Corp., 6612 Snowdrift Road, Allentown, PA� 18106.� Telephone:� 610-395-8445.

 

��� B.� Substitutions will not be acceptable.

 

2.2 MATERIALS

 

��� A.� Precoated Galvanized Steel Sheet:� ASTM A 755/A 755M;� ASTM A 446/A 446M, Grade A, G90 Coating Designation, precoated with Kynar 500�/Hylar 5000� finish.

 

��� B.� Precoated Galvalume Steel Sheet:� ASTM A 792; precoated with Kynar 500�/Hylar 5000� finish.

 

��� C.� Aluminum Sheet:� ASTM B 209, minimum yield strength 17,000 psi.� Prefinish as specified under panel type.

 

2.3 PANEL SYSTEMS

Select system desired and choose appropriate options under each panel type.

 

The Multi-Purpose Panels below successfully renovate industrial, commercial, and professional buildings and prove excellent for new construction as well.� The 17 different profiles offered all present a sleek, smooth appearance, with a positive locking feature and no exposed fasteners.

��� A.� Multi-Purpose Panel System:

������� 1.� Material:� 0.032 inch aluminum.

������� 2.� Material:� 0.040 inch aluminum.

������� 3.� Material:� 24 gage galvanized/Galvalume steel.

������� 4.� Width:� 8-inch panels.

����������� a.� Profile:� Narrow Seam Batten:� MPN080.

����������� b.� Profile:� Wide Batten:� MPW080.

����������� c.� Profile:� Board Batten:� MPH080.

����������� d.� Profile:� Vee Batten:� MPV080.

������� 5.� Width:� 12-inch panels.

����������� a.� Profile:� Narrow Seam Batten:� MPN120.

����������� b.� Profile:� Wide Batten:� MPW120.

����������� c.� Profile:� 5 inch Board Batten:� MPH125.

����������� d.� Profile:� 7 inch Plank Batten:� MPH127.

����������� e.� Profile:� 5 inch Vee Batten:� MPV125.

����������� f.� Profile:� 7 inch Vee Batten:� MPV127.

Note:� The following profile is not available in 0.040 inch aluminum and is 3/8 inch overall depth.

����������� g.� Profile:� Vee Groove:� MPS120.

������� 6.� Width:� 16-inch panels.

����������� a.� Profile:� Narrow Seam Batten:� MPN160.

����������� b.� Profile:� Wide Batten:� MPW160.

����������� c.� Profile:� 5 inch Board Batten:� MPH165.

����������� d.� Profile:� 7 inch Plank Batten:� MPH167.

����������� e.� Profile:� 5 inch Vee Batten:� MPV165.

����������� f.� Profile:� 7 inch Vee Batten:� MPV167.

������� 7.� Panel Depth:� 1-1/4 inches.

Panel lengths are cut to customer specifications and can range from 2 feet to any transportable length.

 

Note:� For panel lengths over 25 feet, the Monarch Panel is recommended because of its clip installation system, which allows the panel to "float" for thermal expansion and contraction without distortion.

������� 8.� Panel Length:� as indicated on drawings.

������� 9.� Panel Length:� ___________________.

������� 10. Texture:� Smooth.

������� 11. Texture:� Stucco Embossed.

������� 12. Finish:� Kynar 500�/Hylar 5000�.

����������� a.� Color:� As indicated on the drawings.

����������� b.� Color:� As selected by Architect from manufacturer's standard colors.

����������� c.� Color:� ___________________.

������� 13. Finish:� Clear Anodized.

������� 14. Finish:� Bronze Anodized.

The Metafor wall panel is applicable to renovations and new construction and can be applied directly to wood or metal framing.� The panel is 12 inches wide and has four ribs spaced 3 inches on center.� Each rib is 1-1/2 inches wide by 5/8 inch deep, providing a consistent overall ribbed texture.

��� B.� Metafor Panel System (MFP120):

������� 1.� Material:� 0.032 inch aluminum.

������� 2.� Material:� 0.040 inch aluminum.

������� 3.� Material:� 0.050 inch aluminum.

������� 4.� Panel Width:� 12 inch coverage.

������� 5.� Panel Depth:� 5/8 inch.

Note:� Panel length may vary from 2 feet to any transportable length.

������� 6.� Panel Length:� As indicated on drawings.

������� 7.� Panel Length:� _______________.

������� 8.� Texture:� Smooth.

������� 9.� Texture:� Stucco Embossed.

������� 10. Finish:� Kynar 500�/Hylar 5000�.

����������� a.� Color:� As indicated on the drawings.

����������� b.� Color:� As selected by Architect from manufacturer's standard colors.

����������� c.� Color:� ___________________.

������� 11. Finish:� Clear Anodized.

������� 12. Finish:� Bronze Anodized. �

The Arc-Metafor system consists of standard Metafor panels that have been custom formed to either a concave or convex shape.� Common applications are mansard profiles or curved fascias and soffits.

��� C.� Arc Metafor Panel System:

������� 1.� Profile:� Concave:� MFV120.

������� 2.� Profile:� Convex:� MFX120.

������� 3.� Material:� 0.032 inch aluminum.

������� 4.� Panel Width:� 12 inch coverage.

������� 5.� Panel Depth:� 5/8 inch.

Note:� Minimum concave radius is 4 feet;� minimum convex radius is 2 feet, 9 inches.

������� 6.� Panel Radius:� As indicated on drawings.

������� 7.� Panel Radius:� _______________.

������� 8.� Texture:� Smooth.

������� 9.� Texture:� Stucco Embossed.

������� 10. Finish:� Kynar 500�/Hylar 5000�.

����������� a.� Color:� As indicated on the drawings.

����������� b.� Color:� As selected by Architect from manufacturer's standard colors.

����������� c.� Color:� ___________________.�

������� 11. Finish:� Clear Anodized.

������� 12. Finish:� Bronze Anodized.

The Opaline panel is a very practical system, offering profiles that look extruded but are more economically rollformed.� Panels are installed in a basic tongue and groove system with mechanical fasteners that are hidden by subsequent panels.

��� D.� Opaline Panel System:

������� 1.� Material:� 0.032 inch aluminum.

������� 2.� Material:� 0.040 inch aluminum.

������� 3.� Material:� 24 gage galvanized/Galvalume steel.

������� 4.� Width:� 4 inch panels.

����������� a.� Profile:� Flush:� OPF040.

����������� b.� Profile:� 1-inch Rib:� OPN041.

����������� c.� Profile:� Curved:� OPV040.

������� 5.� Width:� 4-1/2 inch panels.

����������� a.� Profile:� Ribbed:� OPM045.

����������� b.� Profile:� Flush with 1/2-inch Reveal:� OPW045.

����������� c.� Profile:� Curved with 1/2-inch Reveal:� OPV045.

������� 6.� Width:� 6 inch panels.

����������� a.� Profile:� Flush:� OPF060.

����������� b.� Profile:� 1-inch Rib:� OPN061.

������� 7.� Width:� 6-1/2 inch panels.

����������� a.� Profile:� Flush with 1/2-inch Reveal:� OPW065.

������� 8.� Width:� 8 inch panels.

����������� a.� Profile:� Flush:� OPF080.

����������� b.� Profile:� 1-inch Rib:� OPN081.

������� 9.� Width:� 8-1/2 inch panels.

����������� a.� Profile:� Flush with 1/2-inch Reveal:� OPW085.

������� 10. Panel Depth:� 3/4 inch.

������� 11. Panel Length:� As indicated on drawings.

������� 12. Panel Length:� ___________________.

������� 13. Texture:� Smooth.

������� 14. Texture:� Stucco Embossed.

������� 15. Finish:� Kynar 500�/Hylar 5000�.

����������� a.� Color:� As indicated on the drawings.

����������� b.� Color:� As selected by Architect from manufacturer's standard colors.

����������� c.� Color:� ___________________.

������� 16. Finish:� Clear Anodized.

������� 17. Finish:� Bronze Anodized.

The PC Systems are two piece systems, consisting of a pan and a snapped-on standing seam or batten.� Battens are available in heights of 1 inch and 2 inches, and the standing seam is 1-1/4 inches tall.� These systems are not structural and must be installed over solid underlayment.

��� E.� PC Standing Seam and Batten Style System:

������� 1.� Material:� 0.032 inch aluminum.

������� 2.� Material:� 0.040 inch aluminum.

������� 3.� Material:� 0.050 inch aluminum.

������� 4.� Material:� 24 gage galvanized/Galvalume steel.

������� 5.� Pan Width:� 11-1/4 inches:� PCP110.

������� 6.� Pan Width:� 12-5/8 inches:� PCP120.

������� 7.� Pan Width:� 15-1/4 inches:� PCP150.

������� 8.� Pan Width:� _____________:� PCP999.

������� 9.� Cap Type:� 1-1/4 inch standing seam: �PCS114.

������� 10. Cap Type:� 1-inch high by 1-1/2 inch wide batten:� PCB001;� adds 1-1/4 inch to pan dimension for on center dimension.

������� 11. Cap Type:� 2-inch high by 1-1/2 inch wide batten:� PCB002; adds 1-1/2 inch to pan dimension for on center dimension.

������� 12. Panel Length:� As indicated on drawings.

������� 13. Panel Length:� ___________________.

������� 14. Texture:� Smooth.

������� 15. Texture:� Stucco Embossed.

������� 16. Finish:� Kynar 500�/Hylar 5000�.

����������� a.� Color:� As indicated on the drawings.

����������� b.� Color:� As selected by Architect from manufacturer's standard colors.

����������� c.� Color:� ___________________.

������� 17. Finish:� Clear Anodized.

������� 18. Finish:� Bronze Anodized.

The Field-Lok Seam system is a standing seam system that requires field seaming equipment.� Fastening is by means of clips concealed within the seams;� either fixed or expansion type clips can be used, depending on project conditions.�������

��� F.� Field-Lok Seam System:

������� 1.� Material:� 0.032 inch aluminum.

������� 2.� Material:� 24 gage galvanized/Galvalume steel.

������� 3.� Panel Width:� 12-3/4 inches:� FLS127.

������� 4.� Panel Width:� 16-3/4 inches:� FLS167.

������� 5.� Panel Width:� 21 inches:� FLS210.

������� 6.� Leg Height:� 1-1/2 inches.

������� 7.� Seam Type:� Single lock, field crimped.

������� 8.� Seam Type:� Double fold, field locked.

������� 9.� Installation Clips:� Fixed type:� FLS900.

������� 10. Installation Clips:� Expansion type:� FLS904.

������� 11. Panel Length:� As indicated on drawings.

������� 12. Panel Length:� ___________________.

������� 13. Texture:� Smooth.

������� 14. Texture:� Stucco Embossed.

������� 15. Finish:� Kynar 500�/Hylar 5000�.

����������� a.� Color:� As indicated on the drawings.

����������� b.� Color:� As selected by Architect from manufacturer's standard colors.

����������� c.� Color:� ___________________.

������� 16. Finish:� Clear Anodized.

������� 17. Finish:� Bronze Anodized.

Monarch Roof Panels are one-piece components with an integral seam that conceals the fasteners and clips used for installation.� Available in 3 distinct profiles, Monarch panels have achieved UL 90 ratings for wind uplift.� ASTM E 330 (modified) water and air infiltration tests have also been conducted.

 

Note:� MRC and MRD panels are not available in 0.050 inch aluminum.� Availability of 22 gage steel and copper is subject to minimum quantities and adequate lead time.

��� G.� Monarch Roof Panels:

������� 1.� Material:� 0.032 inch aluminum.

������� 2.� Material:� 0.040 inch aluminum.

������� 3.� Material:� 0.050 inch aluminum.

������� 4.� Material:� 24 gage galvanized/Galvalume steel.

������� 5.� Material:� 22 gage galvanized/Galvalume steel.

������� 6.� Material:� 16 ounce copper.

������� 7.� Material:� 20 ounce copper.

������� 8.� Panel Style:� Batten.

����������� a.� Width:� 12 inches:� MRB120.

����������� b.� Width:� 16 inches:� MRB160.

����������� c.� Panel depth:� 2 inches.

����������� d.� Provide stiffening ribs.

����������� e.� Without stiffening ribs.

������� 9.� Panel Style:� Step Seam.

����������� a.� Width:� 12 inches:� MRC120.

����������� b.� Width:� 16 inches:� MRC160.

����������� c.� Panel depth:� 2-1/2 inches.

����������� d.� Provide stiffening ribs.

����������� e.� Without stiffening ribs.

������� 10. Panel Style:� Dutch Seam.

����������� a.� Width:� 11 inches:� MRD110.

����������� b.� Width:� 15 inches:� MRD150.

����������� c.� Width:� 19-1/4 inches:� MRD194.

����������� d.� Panel depth:� 1-1/2 inches.

����������� e.� Provide stiffening ribs.

����������� f.� Without stiffening ribs.

������� 11. Panel Length:� As indicated on drawings.

������� 12. Panel Length:� ___________________.

������� 13. Texture:� Smooth.

������� 14. Texture:� Stucco Embossed.

������� 15. Finish:� Kynar 500�/Hylar 5000�.

����������� a.� Color:� As indicated on the drawings.

����������� b.� Color:� As selected by Architect from manufacturer's standard colors.

����������� c.� Color:� ___________________.

������� 16. Finish:� Clear Anodized.

������� 17. Finish:� Bronze Anodized.

Scanroof is a metal "tile panel" that simulates the appearance of clay/concrete tile.� An integral purlin gives structural integrity.� Its light weight and high load bearing properties allow maximum spacing between trusses or reduction of roof truss dimensions, up to 4 feet on center, when compared to clay tile.

��� H.� ScanRoof Tile Panel System - SCP163:

������� 1.� Material:� 24 gage galvanized/Galvalume steel.

������� 2.� Panel Size:� 13 feet, 10 inches by 21 inches.

������� 3.� Exposure:� 13 feet, 2 inches by 16-1/2 inches.

������� 4.� Texture:� Scalloped tile configuration, 7-7/8 inch repeat pattern.

������� 5.� Finish:� Kynar 500�/Hylar 5000�.

����������� a.� Color:� As indicated on the drawings.

����������� b.� Color:� As selected by Architect from manufacturer's standard colors.

����������� c.� Color:� ___________________.

The Techo Tile System is a vertical panel with an embossed pattern that simulates Spanish tile.� Panels are 5 "tiles" in width and 3 or more in height.

��� I.� Techo Tile System - TTP400:

������� 1.� Material:� 0.032 inch aluminum.

������� 2.� Material:� 24 gage galvanized/Galvalume steel.

������� 3.� Panel Width:� 42-1/2 inches overall, 40 inches exposed.

Size of each "tile" on a Techo Tile panel is 8 inches in width and 16-1/2 inches in length.� The panel can be produced to lengths that are multiples of the tile length, with a minimum of 3 tiles, or 48 inches.� Stock length is 10 tiles high.

������� 4.� Panel Length:� _________________.

������� 5.� Panel Depth:� 2-1/8 inches.

������� 6.� Texture:� Tile pattern, 0.576 inch step per tile.

������� 7.� Finish:� Kynar 500�/Hylar 5000�.

����������� a.� Color:� As indicated on the drawings.

����������� b.� Color:� As selected by Architect from manufacturer's standard colors.

����������� c.� Color:� ___________________.

The Belvedere system is a structural wall panel in four different styles, offering design freedom for all types of buildings.� It can be installed either on a solid substrate or on spaced framing.

��� J.� Belvedere Wall Panel System:

������� 1.� Profile:� Spanwall - BWS240.

����������� a.� Material:� O.032 inch aluminum, embossed.

����������� b.� Material:� 0.040 inch aluminum, smooth.

����������� c.� Material:� 0.040 inch aluminum, embossed.

����������� d.� Material:� 0.050 inch aluminum, smooth.

����������� e.� Material:� 0.050 inch aluminum, embossed.

����������� f.� Material:� 24 gage galvanized/Galvalume steel, embossed.

����������� g.� Panel width:� 24 inches.

����������� h.� Panel depth:� 4 inches.

������� 2.� Profile:� Box Panel - BWB360.

����������� a.� Material:� 0.032 inch aluminum, embossed.

����������� b.� Material:� 0.040 inch aluminum, smooth.

����������� c.� Material:� 0.040 inch aluminum, embossed.

����������� d.� Material:� 0.050 inch aluminum, smooth.

����������� e.� Material:� 0.050 inch aluminum, embossed.

����������� f.� Material:� 24 gage galvanized/Galvalume steel, embossed.

����������� g.� Panel width:� 36 inches.

����������� h.� Panel depth:� 4 inches.

������� 3.� Profile:� Rib Panel - BWR360.

����������� a.� Material:� 0.032 inch aluminum, smooth.

����������� b.� Material:� 0.032 inch aluminum, embossed.

����������� c.� Material:� 0.040 inch aluminum, smooth.

����������� d.� Material:� 0.040 inch aluminum, embossed.

����������� e.� Material:� 0.050 inch aluminum, smooth.

����������� f.� Material:� 0.050 inch aluminum, embossed.

����������� g.� Material:� 24 gage galvanized/Galvalume steel, smooth.

����������� h.� Material:� 24 gage galvanized/Galvalume steel, embossed.

����������� i.� Material:� 22 gage galvanized/Galvalume steel, smooth.

����������� j.� Material:� 22 gage galvanized/Galvalume steel, embossed.

����������� k.� Panel width:� 36 inches.

����������� l.� Panel depth:� 1-1/2 inches.

Panel lengths for all Belvedere systems are cut to customer specifications, from 5 feet minimum to 40 feet maximum.

������� 4.� Panel Length:� _________________.

������� 5.� Finish:� Kynar 500�/Hylar 5000�.

����������� a.� Color:� As indicated on the drawings.

����������� b.� Color:� As selected by Architect from manufacturer's standard colors.

����������� c.� Color:� ___________________.

 

��� K.� Design Wall System:

������� 1.� Material:� 0.032 inch aluminum.

������� 2.� Material:� 0.040 inch aluminum.

������� 3.� Material:� 0.050 inch aluminum.

������� 4.� Material:� 24 gage galvanized/Galvalume steel.

������� 5.� Panel Width:� 12 inches.

������� 6.� Panel Style:� Provide stiffening ribs.

������� 7.� Panel Style:� Without stiffening ribs.

����������� a.� Panel depth:� 1-3/4 inches:� DSF120.

����������� b.� Panel depth:� 1-1/8 inches:� DWF120.

������� 8.� Panel Profile:� Board type, with adjacent recess and stiffening ribs.

������� 9.� Panel Profile:� Board type, with adjacent recess and without stiffening ribs.

����������� a.� Panel depth:� 1-3/4 inches:� DSH120.

����������� b.� Panel depth:� 1 inch:� DWH120.

����������� c.� Board width:� 6 inches.

����������� d.� Board width:� 7 inches.

����������� e.� Board width:� 8 inches.

����������� f.� Board width:� 9 inches.

����������� g.� Board width:� 10 inches.

����������� h.� Board width:� 11 inches.

������� 10. Panel Length:� As indicated on drawings.

������� 11. Panel Length:� ___________________.

������� 12. Texture:� Smooth.

������� 13. Texture:� Stucco Embossed.

������� 14. Finish:� Kynar 500�/Hylar 5000�.

����������� a.� Color:� As indicated on the drawings.

����������� b.� Color:� As selected by Architect from manufacturer's standard colors.

����������� c.� Color:� ___________________.

������� 15. Venting:� Provide vented panels where indicated.

 

��� L.� Linear Ceiling System:

������� 1.� Style:� Round edge:� LCR.

������� 2.� Style:� Box edge:� LCB.

������� 3.� Texture:� Smooth.

������� 4.� Panel Width:� 4 inch nominal.

������� 5.� Panel Width:� 8 inch nominal.

������� 6.� Panel Width:� 12 inch nominal.

������� 7.� Panel Depth:� 5/8 inch.

������� 8.� Material:� 0.032 inch aluminum.

����������� a.� Finish:� Kynar 500�/Hylar 5000�.

����������� b.� Color:� As indicated on the drawings.

����������� c.� Color:� As selected by Architect from manufacturer's standard colors.

����������� d.� Color:� ___________________.

������� 9.� Material:� 0.020 inch aluminum.

������� 10. Material:� 0.025 inch aluminum.

����������� a.� Finish:� Baked-on enamel.

����������� b.� Color:� As indicated on the drawings.

����������� c.� Color:� As selected by Architect from manufacturer's standard colors.

����������� d.� Color:� ___________________.

������� 11. Closing Strip:� Flush (with LCR Series only).

������� 12. Closing Strip:� Recessed.

The Wind-Lok(TM) panel system has been around for years and is still the best of its type.� These panels can be used for wide overhangs and ceilings both indoors and out.� The Wind-Lok(TM) installation method results in no exposed fasteners, and the panels are available in a wide variety of finishes and colors.� Unlike the tongue and groove method, the panels are hooked into each other, which prevents the panels from sagging in the middle, or slipping apart on wide ceilings.

��� M.� Wind-LokTM Soffit Panel System:

������� 1.� Material:� 0.019 inch aluminum, smooth.

������� 2.� Material:� 0.024 inch aluminum, smooth.

������� 3.� Material:� 0.032 inch aluminum, smooth.

������� 4.� Material:� 0.032 inch aluminum, embossed.

������� 5.� Panel Style:� Smooth:� WLS120.

������� 6.� Panel Style:� Vented:� WLV120.

������� 7.� Panel Width:� 12 inches.

������� 8.� Panel Depth:� 7/16 inch.

������� 9.� Panel Length:� ______________.

������� 10. Finish:� Kynar 500�/Hylar 5000�.

������� 11. Finish:� Siliconized polyester (0.024 inch aluminum only).

������� 12. Finish:� Baked-on enamel (0.019 inch aluminum only).

����������� a.� Color:� As indicated on the drawings.

����������� b.� Color:� As selected by Architect from manufacturer's standard colors.

����������� c.� Color:� ___________________.

������� 13. Finish:� Clear Anodized.

������� 14. Finish:� Bronze Anodized.

 

2.4 ACCESSORIES

 

��� A.� Provide formed accessories of same gage and finish as the primary panel system, unless otherwise indicated on the drawings.

 

��� B.� Sealants:� As specified in Section 07900.

 

��� C.� Fasteners:� As recommended by manufacturer for project conditions and panel type.

 

2.5 FABRICATION

 

��� A.� Panels:� Factory-fabricate all panels with integral lock and seam design.

 

��� B.� Accessories:� Factory-fabricate trim and flashing components in standard 12 foot lengths.

 

��� C.� Form all components true to shape, accurate in size, square and free from distortion or defects.� Cut panels to precise lengths indicated on approved shop drawings.

 

2.6 FINISHES

Delete finishes below not required by panel systems specified.

��� A.� Fluoropolymer Coating:� Provide multi-coat PVDF Kynar 500�/Hylar 5000� finish system on exposed metal surfaces.

 

��� B.� Clear Anodic Coating:� AAM12C22A41 clear anodized coating complying with AAMA 607.1, 0.7 mil thickness� minimum.

 

��� C.� Color Anodic Coating:� AAM12C22A44 coating electrolytically deposited and complying with AAMA 608.1, 0.7 mil thickness minimum.

 

��� D.� Siliconized Polyester Coating:� Manufacturer's standard coating system, factory-applied.

 

��� E.� Baked Enamel Coating:� Manufacturer's standard enamel paint system, factory-applied and baked.

 

 

PART 3� EXECUTION

 

3.1 EXAMINATION

 

��� A.� Inspect substrates to verify that they are in proper condition, spaced correctly, plumb, and are ready to receive work of this section.� Do not proceed with installation until unsatisfactory conditions have been corrected.

 

3.2 INSTALLATION

 

��� A.� Install metal panels and accessories in strict accordance with manufacturer's instructions.

 

��� B.� Protect surfaces in contact with cementitious materials and dissimilar metals with bituminous paint or other coating approved by panel manufacturer.

 

��� C.� Fasten panels to structural support with fasteners provided or approved by panel manufacturer.� Install panels plumb, level, and true to line.

 

��� D.� Fully interlock panels with adjacent panels;� apply sealants as recommended by panel manufacturer to achieve weathertight installation.

Delete paragraph below if no roof panels are required for project, or if ScanRoof or Techo Tile roofing systems are specified.

��� E.� Install roof panels with no transverse seams.

 

��� F.� Remove protective masking from panels immediately after each panel is installed.

 

��� G.� Do not allow shavings or chips to fall on panels.

 

3.3 ADJUSTING AND CLEANING

 

��� A.� Touch up minor abrasions with matching paint provided by panel manufacturer.� Remove and replace panels that cannot be satisfactorily touched up.

 

��� B.� Sweep and remove chips, shavings, and dust from roof on a daily basis during installation period.� Pick up and discard protective masking material previously removed from panels.� Leave installed work clean, free from grease, finger marks and stains.�

 

��� C.� Upon completion of installation, remove scraps and debris from project site.

 

3.4 PROTECTION

 

��� A.� Provide protection as required to assure that completed work of this section will be without damage or deterioration at date of substantial completion.

 

 

����������������������� Back to SPECDISK Table of Contents