������������������������ SECTION 07464
������������������������ VINYL SIDING
PART 1� GENERAL
1.1 SECTION INCLUDES
��� A.� Vinyl siding.
��� B.� Polypropylene siding.
��� C.� Vinyl soffits.
��� D.� Vinyl accessories and trim.
1.2 RELATED SECTIONS
��� A.� Section 06112 - Framing and Sheathing.
��� B.� Section 07900 - Joint Sealers.
1.3 REFERENCES
��� A.� ASTM D 638 -- Standard Test Method for Tensile Properties of Plastics.
��� B.� ASTM D 696 -- Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between -30 Degrees C and 30 Degrees C.
��� C.� ASTM D 790 -- Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials.
��� D.� ASTM D 1435 -- Standard Test Method for Outdoor Weathering of Plastics.
��� E.� ASTM D 1784 -- Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Compounds and Chlorinated Poly (Vinyl Chloride) (CPVC) Compounds.
��� F.� ASTM D 1929 -- Standard Test Method for Ignition Properties of Plastics.
��� G.� ASTM D 2843 -- Standard Test Method for Density of Smoke from the Burning or Decomposition of Plastics.
��� H.� ASTM D 3679 -- Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Siding.
��� I.� ASTM D 4101 -- Standard Specification for Propylene Plastic Injection and Extrusion Materials.
��� J.� ASTM D 4226 -- Standard Test Method for Impact Resistance of PVC Building Products.
��� K.� ASTM D 5206 -- Standard Windload Resistance Test.
��� L.� ASTM E 84 -- Standard test Method for Surface Burning Characteristics of Building Materials.
��� M.� ASTM E 119 -- Standard Test Methods for Fire Tests of Building Construction and Materials.
1.4 PERFORMANCE REQUIREMENTS
��� A.� PVC Fire Resistance:� Provide vinyl siding products that meet or exceed the following ratings:
������� 1.� Flame spread 25, fuel contribution 0, smoke density 330, per ASTM E 84.
������� 2.� Minimum self-ignition temperature of 824 degrees F, per ASTM D 1929.
������� 3.� Fire endurance classification of 1 hour, per ASTM E 119.
��� B.� TPO Fire Resistance:� Provide thermoplastic polyolefin siding products that meet or exceed the following ratings:
������� 1.� Minimum self-ignition temperature of 650 degrees F, per ASTM D 1929.
������� 2.� Smoke density rating of 40, per ASTM D 2843.
1.5 SUBMITTALS
��� A.� Make submittals under provisions of Section 01300.
��� B.� Product Data:� Provide manufacturer's printed information and installation instructions on siding products and accessories.
��� C.� Samples:� Provide 3 samples of siding products in colors specified, not less than 12 inches in length.
1.6 QUALITY ASSURANCE
��� A.� Installer:� Provide installer with not less than three years of experience with products specified.
1.7 WARRANTY
��� A.� Provide manufacturer's standard lifetime limited warranty on siding products, transferable to new owners.
PART 2� PRODUCTS
2.1 MANUFACTURER
��� A.� CertainTeed Corporation, Vinyl Building Products Group, P.O. Box 860, Valley Forge, Pennsylvania� 19482.
��� B.� Substitutions:� Not permitted.
2.2 MATERIALS
��� A.� Polyvinyl Chloride:� Provide siding materials made of PVC resin with cell classification of 13344-B, as defined by ASTM D 1784, meeting or exceeding the following properties:
������� 1.� Impact strength:� 2.20 ft-lbs per inch at test temperature of 73 degrees F., and 1.30 ft-lbs per inch at test temperature of 32 degrees F, per ASTM D 4226.
������� 2.� Tensile strength:� 7,344 psi.
������� 3.� Flexural modulus of elasticity in tension:� 455,750 psi.
������� 4.� Deflection temperature under load of 264 psi:� 168 degrees F.
������� 5.� Coefficient of expansion:� .000034 in/in/degree F.
������� 6.� Chemical resistance:� Excellent.
��� B.� Vinyl Components:� Provide products made of extruded polyvinyl chloride as specified in this section and manufactured to comply with requirements of ASTM D 3679.
������� 1.� Provide elongated nailing slots on nailing flanges to allow for movement.
������� 2.� Factory-notch ends of horizontal panels to form� overlapping joints.
������� 3.� Provide products that meet weathering requirements of ASTM D 1435.
��� C.� Thermoplastic Polyolefin (TPO):� Provide siding materials made of modified polypropylene copolymer with cell classification of PP300A11220F00W00201203, as defined by ASTM D 4101, meeting or exceeding the following properties:
������� 1.� Tensile strength:� 3,500 psi, per ASTM D 638.
������� 2.� Tensile modulus:� 180,000 psi, per ASTM D 638.
������� 3.� Flexural modulus:� 180,000 psi, per ASTM D 790.
������� 4.� Coefficient of linear thermal expansion:� .000053 in/in/degree F, per ASTM D 696.
������� 5.� Deflection temperature at 264 psi:� 160 degrees F.
2.3 SOLID COLOR BOARD STYLE VINYL SIDING
��� A.� Provide siding panels tested per ASTM D 5206 to withstand 78 psf negative wind pressure.
��� B.� Nominal Panel Thickness:� .044 inches, with .088 inch nail hem thickness.
��� C.� Nominal Butt Height:� 3/4 inches, with interlocking, self-aligning joint system.
��� D.� Style:� Double 4 inch clapboard profile, smooth-brushed finish.
��� E.� Style:� Double 4 inch clapboard profile, rough cedar finish.
��� F.� Style:� Double 5 inch clapboard profile, rough cedar finish.
��� G.� Style:� Double 5 inch shiplap profile, rough cedar finish.
��� H.� Style:�� Double 5 inch chamfer board for vertical application, smooth-brushed finish.
��� I.� Color: ______________.
��� J.� Color:� As indicated on drawings.
��� K.� Color:� As selected by Architect from manufacturer's standard colors after award of contract.�
��� L.� Acceptable Product:� CertainTeed Monogram siding.
2.4 SIMULATED CEDAR STAIN BOARD STYLE VINYL SIDING
��� A.� Provide siding panels tested per ASTM D 5206 to withstand 58 psf negative wind pressure.�
��� B.� Nominal Panel Thickness:� .042 inches.
��� C.� Nominal Butt Height:� 5/8 inches, with post-formed locking system for secure installation.
��� D.� Finish:� Low-gloss, cedar-like texture.
��� E.� Style:� Double 4.5 inch clapboard profile.
��� F.� Style:� Double 4.5 inch shiplap profile.
��� G.� Style:� Chamfer board profile for vertical installation.
��� H.� Color:� Glacier Blend.
��� I.� Color:� Mountain Blend.
��� J.� Color:� Canyon Blend.
��� K.� Color:� Desert Blend.
��� L.� Color:� Meadow Blend.
��� M.� Acceptable Product:� CertainTeed Meridian siding.
2.5 SIMULATED CEDAR SHINGLE SIDING
��� A.� Provide siding panels tested per ASTM D 5206 to withstand 70 psf negative wind pressure and meeting weathering requirements of ASTM D 1435.
��� B.� Nominal Panel Thickness: 0.100 inches, with molded lock lugs and integral water drainage flanges.
��� C.� Nominal Butt Height:� 3/8 inches, with integral side locking tabs to provide virtually invisible seams between panels.
��� D.� Perfection Shingles:� 48 inch by 14 inch double course panels, molded from authentic cedar shingle impressions, spectrocolorimeter controlled color throughout.
��� E.� Half-Round Shingles:� 32 inch by 15 inch double course panels, molded from authentic cedar shingle impressions.
��� F.� Color:� Antique Linen.
��� G.� Color:� Desert Tan.
��� H.� Color:� Sterling Gray.
��� I.� Color:� True Taupe.
��� J.� Color:� Rustic Cedar.
��� K.� Color:� Granite Gray.
��� L.� Color:� Natural Clay.
��� M.� Color:� As indicated on the drawings.
��� N.� Color:� As selected by Architect from manufacturer's standards after award of the contract.
��� O.� Acceptable Product:� CertainTeed Cedar Impressions siding.
2.6 VINYL SOFFIT PANELS
��� A.� Provide vinyl soffit panels designed to simulate finished wood.
��� B.� Style:� Monogram Chamfer Board, double 5 inch panels, .044 inches nominal thickness, smooth brushed finish.
������� 1.� Solid type.
������� 2.� Fully vented type, with 7.4 sq. inches free air space per square foot of soffit.
������� 3.� Color:� __________________.
��� C.� Style:� Beaded Porch Panel, triple 2 inch panels, .039 inches nominal thickness, matte finish.
������� 1.� Solid type.
������� 2.� Invisibly vented type, with 1.2 sq. inches free air space per square foot of soffit.
������� 3.� Color:� __________________.
��� D.� Style:� Ironmax, double 5 inch panels, .046 inches nominal thickness, woodgrain finish.
������� 1.� Solid type.
������� 2.� Fully vented type, with 6.4 sq. inches free air space per square foot of soffit.
������� 3.� Color:� __________________.
��� E.� Style:� Certavent T4, triple 4 inch panels, .038 inches nominal thickness, matte finish.
������� 1.� Solid type.
������� 2.� Center vented type, with 1.9 sq. inches free air space per square foot of soffit.
������� 3.� Fully vented type, with 5.9 sq. inches free air space per square foot of soffit.
������� 4.� Color:� __________________.
��� F.� Style:� Certavent 16, triple 5 inch panels, .038 inches nominal thickness, matte finish.
������� 1.� Center vented type, with 2.0 sq. inches free air space per square foot of soffit.
������� 2.� Color:� __________________.
2.7 ACCESSORIES
��� A.� Provide coordinating vinyl accessories for complete and proper installation, whether or not specifically shown on the drawings.
��� B.� Color:� Provide accessories in color matching adjacent siding or soffit panels.
��� C.� Color:� Provide accessories in contrasting color, as follows:� ________________.
��� D.� Profiles:� Provide types as indicated on the drawings.
��� E.� Schedule of Accessories
������� 1.� Starter strip:� Aluminum.
������� 2.� Starter strip:� Vinyl.
������� 3.� Starter strip:� Cedar Impressions.
������� 4.� Undersill trim:� Standard type.
������� 5.� Undersill trim:� Dual type.
������� 6.� Outside corners:� 4-piece system, including 5 inch lineals, quarter round insert, and universal corner starter.
������� 7.� Outside corners:� Single piece corner.
������� 8.� Inside corner post.
������� 9.� Window starters:� 5 inch lineals.
������� 10. Window starters:� 3-1/2 inch lineals.
������� 11. Window and door trim:� 2-1/2 inch standard casing.
������� 12. Gable trim:� 5 inch lineals.
������� 13. Frieze board:� 5 inch lineals.
������� 14. Soffit trim:� F-channels.
������� 15. Soffit trim:� Soffit cove molding.
������� 16. Miscellaneous channels and dividers to suit project conditions.
2.8 FASTENERS
��� A.� Provide galvanized or other corrosion-resistant nails as recommended by manufacturer of siding products.
PART 3� EXECUTION
3.1 EXAMINATION
��� A.� Prior to commencing installation, verify governing dimensions of building and condition of substrate.
3.2 PREPARATION
��� A.� Examine, clean, and repair as necessary any substrate conditions which would be detrimental to proper installation.�
��� B.� Do not begin installation until unacceptable conditions have been corrected.
3.3 INSTALLATION
��� A.� General:� Install products in accordance with the latest printed instructions of the manufacturer, with all components true and plumb.
��� B.� Nailing:� Nail horizontal panels by placing nail in center of slot.� Nail vertical panels by placing first nail at top of top slot and remaining nails in center of slots.� Drive nails straight, leaving 1/16 inch space between nail head and flange of panel.
��� C.� Spacing:� Allow space between both ends of siding panels and trim for thermal movement.� Overlap horizontal panel ends one-half the width of factory pre-cut notches.
��� D.� Joints in Horizontal Siding:� Stagger lap joints in uniform pattern as successive courses of siding are installed.
��� E.� Joints in Vertical Siding:� Install J-channel and flashing to accommodate successive courses of vertical siding.� Install wood shims at building corners to bring cut edges of vertical siding out to correct plane.
3.4 CLEANING
��� A.� At completion of work, remove debris caused by siding installation from project site.
Back to SPECDISK Table of Contents